Telecom LFP 100 and Telecom LFP 150 are
top quality lithium batteries engineered for telecom site
scenarios, featuring industry-leading safety certifications and a 10-year warranty. The LFP 150
adds 50% more capacity in a 4U chassis that is 40 mm deeper, with the same 19-inch width.
UL1973UL9540UL9540A
Plug & Play · Telecom LFP 100
Lug-free cable connections
Power cables plug straight into the LFP 100's front-panel connectors — no ring lugs to
crimp or bolt down.
150 A terminal blocks for ring lugs · 40 mm deeper
Same 19-inch width, front-panel layout and communication ports on both models. The LFP 150 is
40 mm deeper and takes ring-lug power cables; the LFP 100 connects lug-free, plug and play.
Key Specifications
5.2 / 7.8
kWh
Energy Capacity (LFP 100 / 150)
100 / 150
Ah
Ampere-Hours (LFP 100 / 150)
51.2
Vdc
Nominal Voltage (57 Vdc charge)
6000
cycles
Cycle Life
10
years
Warranty
16
cells
Cell Configuration
Electrical Specifications
Energy
5.2 kWh (LFP 100) · 7.8 kWh (LFP 150)
Capacity
100 Ah (LFP 100) · 150 Ah (LFP 150)
Nominal Voltage
51.2 Vdc
Charge Voltage
57 Vdc
Discharge Rate
1C - 1.5C
Cell Count
16 cells (series)
Breaker
125A (LFP 100) · 150A (LFP 150), with BMS switch
Communication
Open Modbus
Physical Specifications
Form Factor
19" and 23" rack mount
Height
3U (LFP 100) · 4U (LFP 150)
Depth
21.3 in (541 mm, LFP 100) · 22.9 in (581 mm, LFP 150)
Connector
Lug-free, plug & play (LFP 100) · 150 A lug terminal blocks (LFP 150)
Rack Option
19" 7ft indoor rack
Kit Included
19" to 23" installation
Electrical Safety
Comprehensive Protection
The Telecom LFP 100 and LFP 150 are engineered for maximum safety with embedded protection mechanisms.
• UL Certified: Meets rigorous
safety standards.
• Embedded Breaker: 125A (LFP 100) / 150A (LFP 150) DC breaker
for overcurrent protection.
• BMS Switch: AI-managed Battery Management System switch for automated
safety control.
Thermal Safety
No Thermal Runaway Risk
LiFePO₄ chemistry produces no oxygen at 300°C,
eliminating thermal runaway risk.
To achieve the 6000 cycle life, our BMS optimizes the
Depth of Discharge (DoD). Operating at 80% DoD significantly extends the service life
compared to full discharges.
Optional: 19" 7ft indoor rack available upon request.
Evolution
Battery Roadmap
Telecom LFP 100
Shipping since 2025
Engineering Changes
51.2 V lithium iron phosphate pack, 16-cell series string
3U, 19-inch rack-mount
BMS with RS485 Modbus and SNMP, integration-tested with common site controllers
UN 38.3 tested, Class 9 shipping certification
Lug-free, plug-and-play power connectors
Capacity, Runtime & Site Impact
Reference unit: 100 Ah / 5.2 kWh in 3U, 1.7 kWh per rack unit
What it means: The baseline every delta in this roadmap is measured
against.
Telecom Sodium 160
Launched 2026
Engineering Changes
Sodium-ion cells, lithium-free chemistry
48 V class, 16-cell series string
5.2U, 19-inch rack-mount
Integrated cell-heating option for sub-zero charging
BMS with RS485 Modbus and CAN, SNMP option
Capacity, Runtime & Site Impact
Capacity +60% (160 Ah, about 7.7 kWh)
Discharge rated to −40 °C
Cycle life 8,000+
Ships and stores at 0 V (sodium-ion transport class)
Energy per rack unit 1.5 kWh/RU (−14%)
What it means: +60% backup runtime at the same load in 2.2 extra rack
units; unheated-enclosure discharge at −40 °C; safer logistics with fully
discharged transport
Telecom LFP 150
Now available
Engineering Changes
150 Ah-class prismatic lithium iron phosphate cells, 16-cell series string
4U, 19-inch rack-mount, same width as LFP 100 with a deeper chassis
Barrier terminal blocks for ring-lug power cables, with clear flip covers
Power path rated for the 150 Ah pack (bus bars, breaker, MOSFET stage)
BMS protocol stack carried over from LFP 100
UL 1973, UL 9540 and UL 9540A
Capacity, Runtime & Site Impact
Capacity +50% (150 Ah, 7.8 kWh)
Energy per rack unit +12.5% (1.95 vs 1.73 kWh/RU)
+1U height, deeper chassis
What it means: +50% backup runtime at the same load, or the same
runtime from fewer strings; 12.5% more stored energy per cabinet rack unit
LFP 100 to LFP 150: capacity +50%, energy per rack unit +12.5%.
Sodium 160 trades rack space for −40 °C discharge, 8,000+ cycles and 0 V transport.
Capacity and energy figures are nominal. Runtime deltas assume equal load and depth of discharge.